Research Trends of Polymer Film for Radiation Radiotherapy: A Review
DOI:
10.56566/jmsr.v2i1.690Downloads
Abstract
Polymer-based radiation dosimeters have attracted significant attention in recent years due to their capability to measure complex radiation dose distributions in radiotherapy applications. This study aims to analyze the research trends related to polymer film and polymer gel dosimetry used in radiotherapy through a systematic literature review and bibliometric analysis. The study employed the PRISMA methodology to systematically identify and select relevant publications from the Scopus and SINTA databases. A total of 30 articles published between 2018 and 2025 were included in the analysis. Bibliometric analysis was conducted using VOSviewer to examine publication trends, keyword co-occurrence networks, and research collaboration patterns. The results indicate a steady increase in research publications related to polymer dosimetry over the past decade. Keyword clustering analysis revealed several dominant research themes, including polymer gel dosimetry, radiation polymerization, dose distribution measurement, polymer film dosimeters, and nanoparticle-enhanced polymer materials. Among these topics, polymer gel dosimetry remains the most widely studied due to its capability to record three-dimensional radiation dose distributions. However, recent studies have increasingly explored polymer film dosimeters and nanocomposite materials to improve radiation sensitivity and dosimetric performance. Overall, the findings highlight the rapid development of polymer dosimetry technologies and their growing importance in modern radiotherapy quality assurance. Future research should focus on developing advanced polymer nanocomposites and integrating imaging-based dosimetry techniques to improve radiation dose measurement accuracy and clinical applicability.
Keywords:
Polymer film dosimeter Polymer gel dosimetry Radiation dosimetry Radiotherapy ReviewReferences
Alqathami, M., Blencowe, A., Geso, M., & Ibbott, G. (2019). Quantitative 3D radiochromic dosimetry: A review. Radiation Physics and Chemistry, 165, 108389. https://doi.org/10.1016/j.radphyschem.2019.108389
Aria, M., & Cuccurullo, C. (2017). Bibliometrix: An R-tool for comprehensive science mapping analysis. Journal of Informetrics, 11(4), 959–975. https://doi.org/10.1016/j.joi.2017.08.007
Baldock, C., Deene, Y., Doran, S., Ibbott, G., Jirasek, A., Lepage, M., & Schreiner, L. (2010). Polymer gel dosimetry. Physics in Medicine & Biology, 55(5), 1. https://doi.org/10.1088/0031-9155/55/5/R01
Chen, Y., Zhang, H., Liu, X., Wang, J., & Li, Z. (2021). Polymer film dosimeters for radiation therapy QA. Polymers, 13(5), 721. https://doi.org/10.3390/polym13050721
Deene, Y. (2022). Radiation dosimetry using radiosensitive hydrogels and polymers. Gels, 8(9), 599. https://doi.org/10.3390/gels8090599
Devic, S. (2019). Radiochromic film dosimetry: Past, present, and future. Physica Medica, 60, 61–72. https://doi.org/10.1016/j.ejmp.2019.03.012
Donthu, N., Kumar, S., Mukherjee, D., Pandey, N., & Lim, W. M. (2021). How to conduct a bibliometric analysis: An overview and guidelines. Journal of Business Research, 133, 285–296. https://doi.org/10.1016/j.jbusres.2021.04.070
Doyan, A., Susilawati, S., Annam, S., Ardianto, T., Ikhsan, M., Ardianti, N. R., & Hamidi, H. (2025). Trend Research of Polymer Gel Dosimetry: A Systematic Review. Journal of Material Science and Radiation, 1(1), 21–28. Retrieved from https://journals.balaipublikasi.id/index.php/jmsr/article/view/362
Eck, Jan, N., & Waltman, L. (2010). Software Survey: VOSviewer, a Computer Program for Bibliometric Mapping. Scientometrics, 84(2), 523–38. https://doi.org/10.1007/s11192-009-0146-3.
Farhood, B., Geraily, G., & Abtahi, S. M. (2019). Polymer gel dosimeters in radiotherapy: A systematic review. Applied Radiation and Isotopes, 143, 47–59. https://doi.org/10.1016/j.apradiso.2018.08.018
Gambarini, G., Carrara, M., & Villa, R. (2020). Polymer gel dosimetry: Current status and future trends. Radiation Measurements, 135, 106305. https://doi.org/10.1016/j.radmeas.2020.106305
Ghorbani, M., Behmadi, M., & Haghparast, A. (2020). Nanoparticle-enhanced radiation dosimetry: A review. Radiation Physics and Chemistry, 168, 108536. https://doi.org/10.1016/j.radphyschem.2019.108536
Gupta, P., Singh, R., Kumar, A., & Sharma, S. (2023). Radiation-induced polymerization in dosimetric films. Journal of Applied Polymer Science. https://doi.org/10.1002/app.53345
Hosseini, S. A., Shahbazi-Gahrouei, D., & Baradaran-Ghahfarokhi, M. (2019). Polymer gel dosimetry in IMRT verification. Radiation Oncology, 14, 123. https://doi.org/10.1186/s13014-019-1304-6
Husseini, G. A., & Pitt, W. G. (2022). Biopolymer-based materials for biomedical applications. International Journal of Pharmaceutics, 620, 121740. https://doi.org/10.1016/j.ijpharm.2022.121740
Issa, A., Mahmoud, M., & El-Khatib, A. (2023). Development of radiation-sensitive hydrogel dosimeters. Radiation Physics and Chemistry, 205, 110543. https://doi.org/10.1016/j.radphyschem.2023.110543
Kalantari, F., Mowlavi, A. A., & Mohammadi, S. (2021). Application of artificial intelligence in radiation dosimetry. Radiation Physics and Chemistry, 181, 109335. https://doi.org/10.1016/j.radphyschem.2020.109335
Karger, C. P., Elter, A., Dorsch, S., Mann, P., Pappas, E., & Oldham, M. (2024). Validation of complex radiotherapy techniques using polymer gel dosimetry. Physics in Medicine & Biology, 69(6), 06TR01. https://doi.org/10.1088/1361-6560/ad278f
Kaur, M., Singh, R., & Sharma, P. (2021). Radiation-sensitive polymer gel dosimeters for clinical radiotherapy. Radiation Physics and Chemistry, 184, 109655. https://doi.org/10.1016/j.radphyschem.2021.109655
Kawamura, H., Sato, T., & Nakagawa, K. (2018). Investigation of temperature dependence of polymer gels. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 7(2), 197–206. https://doi.org/10.4236/ijmpcero.2018.72022
Kitchenham, B., Brereton, P., Budgen, D., Turner, M., Bailey, J., & Linkman, S. (2009). Systematic literature reviews in software engineering – A systematic literature review. Information and Software Technology, 51(1), 7–15. https://doi.org/10.1016/j.infsof.2008.09.009
Kozicki, M., Maras, P., & Dudek, M. (2024). Polymer gel dosimeters with CBCT reading. Materials, 17(6). https://doi.org/10.3390/ma17061283
Lee, H., Kim, J., Park, S., & Choi, Y. (2022). Optical analysis of polymer film dosimeters. Sensors, 22(5). https://doi.org/10.3390/s22051843
Mahmood, S., Ali, N., & Ahmad, R. (2023). Machine learning approaches in medical dosimetry. Medical Physics, 50(4), 2345–2358. https://doi.org/10.1002/mp.16234
Marroquin, E. Y., Herrera, M., & Vega, R. (2020). Stability of polymer gel dosimeters: A review. Radiation Measurements, 137, 106412. https://doi.org/10.1016/j.radmeas.2020.106412
Molham, M. K., Al-Zahrani, S., & Al-Shehri, A. (2023). Polymer gel dosimeter with glucose additive. Radiation Measurements, 165, 106983. https://doi.org/10.1016/j.radmeas.2023.106983
Niroomand-Rad, A., Blackwell, C. R., & Coursey, B. M. (2018). Radiochromic film dosimetry: Recommendations of AAPM. Medical Physics, 45(10), 825– 844. https://doi.org/10.1002/mp.13139
Oflaz, K., Oflaz, Z., Ozaytekin, I., Dincer, K., & Barstugan, R. (2021). Time and volume‐ratio effect on reusable polybenzoxazole nanofiber oil sorption capacity investigated via machine learning. Journal of Applied Polymer Science, 138(30), 50732. https://doi.org/10.1002/app.50732
Oldham, M. (2004). Optical-CT scanning of polymer gels. Journal of Physics: Conference Series, 3(1), 122–135. https://doi.org/10.1088/1742-6596/3/1/011/meta
Oldham, M. (2019). 3D dosimetry technologies for radiation therapy. Journal of Physics: Conference Series, 1305, 12001. https://doi.org/10.1088/1742-6596/1305/1/012001
Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., Chou, R., Glanville, J., Grimshaw, J. M., Hróbjartsson, A., Lalu, M. M., Li, T., Loder, E. W., Mayo-Wilson, E., McDonald, S., & Moher, D. (2021). The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. Systematic Reviews, 10(1), 89. https://doi.org/10.1186/s13643-021-01626-4
Rabaeh, K., Al-Zoubi, A., & Al-Nimr, A. (2022). Polymer hydrogel dosimeters for radiation measurement. Polymers, 14(3), 578. https://doi.org/10.3390/polym14030578
Rahman, M. S., Hasan, M. S., & Islam, M. T. (2020). Biopolymer-based hydrogels for radiation dosimetry. Radiation Physics and Chemistry, 172, 108765. https://doi.org/10.1016/j.radphyschem.2020.108765
Salman, M. D., Hassan, A. M., & El-Khatib, A. M. (2025). PMMA polymer gel dosimeter doped with CuO nanoparticles. Polymer Bulletin. https://doi.org/10.1007/s00289-025-05863-8
Schreiner, L. J. (2018). Review of polymer gel dosimeters. Journal of Physics: Conference Series, 1021, 12001. https://doi.org/10.1088/1742-6596/1021/1/012001
Shakeri, M., Ghorbani, M., & Mahdavi, S. R. (2021). Dose enhancement in polymer dosimeters using nanoparticles. Applied Radiation and Isotopes, 174, 109789. https://doi.org/10.1016/j.apradiso.2021.109789
Sharma, S., Gupta, P., & Singh, R. (2022). Advances in polymer dosimeters for radiotherapy QA. Radiation Measurements, 154, 106676. https://doi.org/10.1016/j.radmeas.2022.106676
Singh, R., Kaur, M., & Sharma, P. (2022). Hydrogel-based radiation dosimeters. Materials, 15(5). https://doi.org/10.3390/ma15051872
Susilawati, S., Doyan, A., Annam, S., Ardianto, T., Ikhsan, M., & Ardianti, N. R. (2025). A Systematic Review: Trend Research of Polymer Thin Film Dosimetry. Journal of Material Science and Radiation, 1(1), 36–43 ,. Retrieved from https://journals.balaipublikasi.id/index.php/jmsr/article/view/363
Wang, L., Liu, Y., Chen, H., & Zhang, Q. (2024). Radiochromic elastomer dosimeter. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.3c17945
Zhang, Y., Li, H., Wang, X., & Chen, J. (2024). Polymer-based radiation dosimetry materials. Advanced Functional Materials. https://doi.org/10.1002/adfm.202402341
Zupic, I., & Čater, T. (2015). Bibliometric methods in management and organization. Organizational Research Methods, 18(3), 429–472. https://doi.org/10.1177/1094428114562629
License
Copyright (c) 2026 Aris Doyan, Susilawati, Syarful Annam, Muhammad Ikhsan, Nuraini Rachma Ardianti

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with Journal of Material Science and Radiation, agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution 4.0 International License (CC-BY License). This license allows authors to use all articles, data sets, graphics, and appendices in data mining applications, search engines, web sites, blogs, and other platforms by providing an appropriate reference. The journal allows the author(s) to hold the copyright without restrictions and will retain publishing rights without restrictions.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in Journal of Material Science and Radiation.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).


